Free Pump Seal Failure Inspection Checklist

A practical, printable checklist for operators and maintenance technicians who need to inspect a leaking pump seal safely.

Cal West Mashy Company supplies mixers, pumps, and related process equipment in Northern California, Western Nevada, and the Pacific Northwest. Download the free checklist, then call 888-841-3335 if you need help.

What's in the checklist

The free Pump Seal Failure Inspection Checklist covers safety first, including lockout/tagout, the fluid's SDS and required PPE, and isolating the area if the leaking fluid is hazardous; shutting down the pump and isolating it by closing the suction and discharge valves; visual leak checks and operating conditions to record; possible causes to check, such as running dry, overheating, cavitation, or misalignment; and when not to restart, including not restarting a pump whose seal is leaking heavily. It is a general aid. It does not give torque values, temperatures, intervals, or other operating limits.

If a pump seal is leaking right now

Safety comes first. Follow your plant's lockout/tagout procedure and the fluid's safety data sheet (SDS) and required PPE, and if the leaking fluid is hazardous, isolate the area and alert the right people. Then shut down the pump and isolate it by closing the suction and discharge valves. Contain and clean up the leak according to your site procedures. Note how bad the leak is and the operating conditions at the time, and check for a cause such as the pump running dry or overheating. Do not restart a pump whose seal is leaking heavily. Then call Cal West Mashy for details at 888-841-3335.

Use these steps, and use the checklist to record what you find:

Step 1. Follow your plant's lockout/tagout procedure and the fluid's safety data sheet (SDS) and required PPE, and if the leaking fluid is hazardous, isolate the area and alert the right people.

Step 2. Shut down the pump and isolate it by closing the suction and discharge valves.

Step 3. Contain and clean up the leak according to your site procedures.

Step 4. Note how bad the leak is and the operating conditions at the time, and check for a cause such as the pump running dry or overheating.

Step 5. Do not restart a pump whose seal is leaking heavily.

Step 6. Then call Cal West Mashy for details at 888-841-3335.

Download the free checklist

Complete the form on this page. After you submit it, you will be taken to a page where you can download the Pump Seal Failure Inspection Checklist.

Frequently asked questions

What is included in the free pump seal failure inspection checklist?

The free Pump Seal Failure Inspection Checklist covers safety first, including lockout/tagout, the fluid's SDS and required PPE, and isolating the area if the leaking fluid is hazardous; shutting down the pump and isolating it by closing the suction and discharge valves; visual leak checks and operating conditions to record; possible causes to check, such as running dry, overheating, cavitation, or misalignment; and when not to restart, including not restarting a pump whose seal is leaking heavily. It is a general aid. It does not give torque values, temperatures, intervals, or other operating limits.

Is this checklist a substitute for my plant's procedures or the manufacturer's manual?

No. This checklist is a general aid for plant personnel. It is not a substitute for your plant's lockout/tagout and safety procedures, the fluid's safety data sheet (SDS) and required PPE, the pump manufacturer's instructions, or applicable regulations.

How do I download the checklist?

Complete the form on this page. After you submit it, you will be taken to a page where you can download the Pump Seal Failure Inspection Checklist.

Who is Cal West Mashy, and where do you work?

Cal West Mashy Company supplies mixers, pumps, and related process equipment in Northern California, Western Nevada, and the Pacific Northwest. Call 888-841-3335. For parts requests, contact Sydney Allen at 888-841-3335, ext. 901.

What should I do if a pump seal is leaking right now?

Safety comes first. Follow your plant's lockout/tagout procedure and the fluid's safety data sheet (SDS) and required PPE, and if the leaking fluid is hazardous, isolate the area and alert the right people. Then shut down the pump and isolate it by closing the suction and discharge valves. Contain and clean up the leak according to your site procedures. Note how bad the leak is and the operating conditions at the time, and check for a cause such as the pump running dry or overheating. Do not restart a pump whose seal is leaking heavily. Then call Cal West Mashy for details at 888-841-3335.

Cal West Mashy Company · 888-841-3335 · info@calwestmashy.com · www.calwestmashy.com