Dickow's mechanical seal process pumps are the NKL light duty pump for heat transfer media, the NCL medium duty centrifugal pump for chemical and refinery service, and the NHL, NHM, HPL and HPR hot water circulation pumps for heating plants. Call Cal West Mashy at 888-841-3335.
The NKL follows EN 733 and serves as a circulating pump in industrial heating plants, running to 340°C without additional cooling. The NCL follows ISO 2858 and reaches 900 m³/h (3,960 gpm). The NHL is rated to 45 bar at 238°C, and the HPL and HPR to 80 bar at 280°C.